SX-20BZA Hydrocarbon Hydronic Heating Air Sourced Heat Pump

AVAILABLE FROM ALL LEADING HYDRONIC HEATING SPECIALISTS - INSIST ON THE BEST

For heating up to about 200sqm floorspace for concrete slab heating (45oC)
For heating up to about 160sqm floorspace for panel radiators (55oC)

Our SX-20BZA Hydrocarbon Hydronics Heat Pump is not an "off-the-shelf" import, it is unique and purpose-built to heat water for hydronic heating systems. The cabinet and refrigeration system is pre-assembled to our design.
We finish them locally, fit compressors, charge them with Hydrocarbons, install control systems, then fine-tune and put each heat pump through quality assurance testing.

Over the years we have developed our own inhouse heatpump tuning/monitoring rig.
Every machine that leaves our factory has been fine-tuned for its application, has been "run-in" for hours, and is shipped with its own performance guarantee.
When it is delivered and installed, it will work faultlessly from day one.

The SX-20BZA can heat water to a maximum of 55oC
, (recommend design for 50oC for new radiator installations). The dual compressor SX-20ZA can be spanned across 2 phases if you have 2 phase supply, or across 2phases of a 3ph supply.

Skyline Energy SX-24 Air Sourced Hydrocarbon Heat Pump
       3yrs return to base warranty

Technical data:

  • Nominal input power: 3.8kW - 4.8kW
  • Voltage: 220V (can be spanned across 2ph)
  • Pipe size: DN32
  • Max outlet water: 55oC
  • Environment range: -19oC to +45oC
  • Compressor: 2x 2.33HP Copeland ZR28K3E-PFJ-522 scroll
  • Refrigerant: Hydrocarbons
  • Weight: 200Kg
  • Sound Level: 60dBa
  • Dimension: 1450x800x1060mm
  • Warranty: 3yrs *for all systems delivered after Jan 2017
    Subject to suppliers sizing and installation guidelines being followed
    *(there may be a travel charge for on-site service if there is a significant distance)

Specifications are subject to change without notice

Download SX-20BZA data sheet


We use Natural Organic hydrocarbons:

Our hydronic heat pumps use hydrocarbon instead of traditional refrigerant, a highly efficient blend of R290 and R170, propane and ethane. When switching from R22, R502, R407C, and R404A power bills can be dramatically reduced, and the wear and tear on the refrigeration system can also be minimised.

It's the Natural Organic solution

Efficient and economical - The superior efficiency of naturally occurring hydrocarbon gases, which are purified and precision blended, combined with reduced charge weight results in great cost savings and on-going electricity savings for the user.


Compliant with a number of national and international standards, such as: ISO 5149, the ISO/IEC 60335 series, BS 4434Ė1995 as well as AS/NZS 1677, which also covers the professional use of hydrocarbon refrigerants in Australia

Skyline Energy SX-24ZA heatpump with Super Efficient Super Quiet OWLET fans fitted  ziehl-abegg OWL fan 152x150

Hi-Tech Low Noise Fan option

For up to 15% higher fan efficiency and especially for installations where sound level could be an issue, we recommend using super-efficient low-noise Ziehl-Abegg "Owlet" axial fans.

We welcome trade enquiries! - 1300 552 976
RRP $10,600* incl GST with super-efficient low-noise Ziehl-Abegg "Owlet" axial fans

plus delivery & installation * prices are subject to change without notice, so please call for latest pricing - special promotions etc.

Recommended Primary Circulation Pump for SX-20BZA

GPD25-8S hot water circulating pump

We offer a small range of circulating pumps to suit a variety of applications.

An essential part of any hydronic heating system is the circulating pump or pumps.

The following table lists a range of circ. pumps to compliment our Air Sourced Hydronic Heat Pumps as primary circuit pump between the heat pump and the buffertank, and as the 'zone' pump(s) which circulate the water between the buffertank and the floorcoils and/or radiator panels.

The primary circulation pump must be matched to the flow-rate required by the heat pump.

The secondary or zone pumps are usually 0.5 to 1.5 Litres per second.

Some of our circulating pumps have 3 speeds to allow for varying conditions:

Model

Body

Speed

Conn's

Head

Watts

Flow Rate

R.R.P.

Comment

>GPD25-6S<

C.I.

3 sp

25mm

2.5m

100/70/55

1.0L/s@1.8m

$216

hydronics multi-zone pump(s)

>GPD25-8S<

C.I.

3 sp

25mm

8m

245

1.4L/s@5m

$338

hydronics single-zone pump

>GPD32-9<

C.I.

1 sp

32mm

5m

300

1.6L/s@5m

$497

SX-20BZA primary circuit pump (close-coupled buffertank)

>GPD32-12<

C.I.

1 sp

32mm

5m

500

2.5L/s@5m

$616

SX-20BZA primary circuit pump (remote-coupled buffertank)

Recommend Purpose-made 200Lt stainless steel buffertank

With the SX-20BZA we recommend using a 200Lt buffertank.

Installing a buffertank on a hydronic heat-pump allows for zoning without causing backpressure or flow-rate fluctuations which may trip the heat-pump.

Hydronic Buffertanks also reduce short-cycling which increases efficiency.

With a heat-pump hydronic system, heat energy is always readily available so a larger buffertank is not necessary and in fact can reduce efficiency. (one reason why we don't recommend multiple potable hot water heat-pumps for hydronics)

Skyline Energy Stainless Steel Hydronic Buffertanks and Hydronic Circulating Pumps
         

Other Models:

Simplified rules for sizing your heatpump for hydronic heating

- for MAXIMUM EFFICIENCY AND SERVICE LIFE!

  • Calculate how many kW are required
  • Look at the climatology of the location to establish the duration of 0oC to +4oC. Donít just look at the extreme temps, look at the mean overnight temp and duration
  • If the ambient air temp rarely dips below +4oC or does so for short periods then you can use this simple calculation...
        3.3 x electricity input kW = heatpump output heat kW to size the heatpump.
  • If the mean overnight ambient air temp is between 0oC and +4oC change the calculation to
        2.2 x electricity input kW = heatpump output heat kW to size the heatpump.
  • A more powerful heatpump will raise the water temp more rapidly so it will cycle off before it needs to defrost,
    thereby maintaining a higher COP and efficiency.
  • Warranty service may be refused if our sizing guidelines are ignored.

MODEL

POWER

COMPRESSOR

AIR

5 STAR CAPABILITY

 

 

QTY

Brand Model

DISCHARGE

(5 star energy construction rating)

220V 1ph

>> SX-06

220V, 1ph

1x

Mitsubishi Rotary RN145V, 1.0HP

1x fan - side

up to 48sqm radiators or 60sqm slab

>> SX-08

220V, 1ph

1x

Mitsubishi Rotary RN222VHFMC, 2.5HP

1x fan - side

up to 67sqm radiators or 85sqm slab

>> SX-11CCZA

220V, 1ph

1x

Copeland ZR28K3E-PFJ-522, 2.33HP

2x fan - side

up to 90sqm radiators or 110sqm slab

>> SX-13CCZA

220V, 1ph

1x

Copeland ZR34K3E-PFJ-522, 2.83HP

2x fan - side

up to 100sqm radiators or 130sqm slab

>> SX-15CCZA

220V, 1ph

1x

Copeland ZR42K3E-PFJ-522, 3.5HP

2x fan - side

up to 120sqm radiators or 150sqm slab

>> SX-17CCZA

220V, 1ph

1x

Copeland ZR47K3E-PFJ-522, 4.0HP

2x fan - side

up to 140sqm radiators or 170sqm slab

 

 

 

 

 

 

220V 1ph or 2ph (dual compressor)

>> SX-20BZA

220V, 1-2ph

2x

Copeland ZR28K3E-PFJ-522, 2.33HP

2x fan - top

up to 160sqm radiators or 200sqm slab

>> SX-24ZA

220V, 1-2ph

2x

Copeland ZR34K3E-PFJ-522, 2.83HP

2x fan - top

up to 200sqm radiators or 240sqm slab

V-Models are recommended for heavy frost-prone areas

>> V20ZA

220V, 1-2ph

2x

Copeland ZR28K3E-PFJ-522, 2.33HP

2x fan - V evap, top

up to 160sqm radiators or 200sqm slab

>> V25ZA

220V, 1-2ph

2x

Copeland ZR34K3E-PFJ-522, 2.83HP

2x fan - V evap, top

up to 210sqm radiators or 250sqm slab

>> V30ZA

220V, 1-2ph

2x

Copeland ZR42K3E-PFJ-522, 3.5HP

2x fan - V evap, top

up to 250sqm radiators or 300sqm slab

>> V35ZA

220V, 1-2ph

2x

Copeland ZR47K3E-PFJ-522, 4.0HP

2x fan - V evap, top

up to 300sqm radiators or 350sqm slab

 

 

 

 

 

 

380V 3ph (dual compressor)

>> V42-3

380V 3ph

2x

Copeland ZR61K3-TFD-522, 5.0HP

2x fan - V evap, top

up to 350sqm radiators or 420sqm slab

>> V50-3

380V 3ph

2x

Copeland ZR72KC-TFD-522, 6.0HP

2x fan - V evap, top

up to 400sqm radiators or 500sqm slab

>> V60-3

380V 3ph

2x

Copeland ZR94KC-TFD-522, 8.0HP

2x fan - V evap, top

up to 480sqm radiators or 600sqm slab

Can't find what you want - maybe we can build it for you - ASK!


Please call for trade pricing

For all enquiries, please call the national number below

or email

NATIONAL DISTRIBUTION CALL CENTRE:
1300 552 976

Skyline Energy - 21st Century Heating Solutions