SX-13CC/SX-13CCZA Hydrocarbon Hydronic Heating Air Sourced Heat Pump

For heating up to about 100sqm floorspace for panel radiators

For heating up to about 130sqm floorspace for concrete slab heating

Our SX-13CC/SX13CCZA Hydronics Heat Pump is not an "off-the-shelf" import, it is unique and purpose-built to heat water for hydronic heating systems. The cabinet and refrigeration system is pre-assembled to our design. We finish them locally,charge them with Hydrocarbons, then fine-tune and put each heat pump through quality assurance testing.

We use Natural Organic hydrocarbons:
Our hydronic heat pumps use hydrocarbon instead of traditional refrigerant, a highly efficient blend of R290 and R170, propane and ethane. When switching from R22, R502, R407C, and R404A power bills can be dramatically reduced, and the wear and tear on the refrigeration system can also be minimised.

It's the Natural Organic solution

We offer ZA Hi-Tech Low Noise Owlet axial fan option:
Improved airflow and up to 15% higher fan efficiency
Especially for installations where noise could be an issue, we recommend using the ZA model with super-efficient low-noise Ziehl-Abegg "Owlet" axial fans.

Skyline Energy SX-13CC air sourced hydronic Heat-Pump    Skyline Energy SX-13CC air sourced hydronic Heat-Pump    Skyline Energy SX-13CC air sourced hydronic Heat-Pump

Over the years we have developed our own inhouse heatpump tuning/monitoring rig.
Every machine that leaves our factory has been fine-tuned for its application, has been "run-in" for hours, and is shipped with its own performance guarantee.
When it is delivered and installed, it will work faultlessly from day one.


The SX-13CC/SX-13CCZA can heat water to a maximum of 55oC
, (recommend design for 50oC for new radiator installations)

Skyline Energy SX-13CC air sourced hydronic Heat-Pump
       3yrs return to base warranty

See below for tips on sizing your heatpump for MAXIMUM EFFICIENCY AND SERVICE LIFE!

Technical data:

  • Nominal input power: 2.3kW - 3kW
  • Voltage: 220V
  • Pipe size: DN25
  • Max outlet water temp: 55oC
  • Environment range: -19oC to +45oC
  • Compressor: Copeland ZW34 Scroll
  • Refrigerant: Hydrocarbons
  • Weight: 160Kg
  • Dimension: 1120x490x1270mm
  • Dimension *ZA: 1120x650x1270mm
  • Warranty: 3yrs *for all systems delivered after Jan 2017
    Subject to suppliers sizing and installation guidelines being followed
    *(there may be a travel charge for on-site service if there is a significant distance)

*Cabinet for ZA fan model is basically same size but the ZA Owlet axial fans protrude further out.


Download SX-13CC data sheet
Download SX-13CCZA data sheet

Skyline Energy SX-13CCZA Hydrocarbon Hydronic Heatpump
Performance Chart:

Skyline Energy SX-13CCZA Hydronic Heat Pump

Specifications are subject to change without notice

RRP $6,400* incl GST
RRP $7,300* incl GST for ZA model with low-noise Ziehl-Abegg "Owlet" axial fans

plus delivery & installation * prices are subject to change without notice, so please call for latest pricing - special promotions etc.

We welcome trade enquiries! - 1300 552 976


Recommended Primary Circulation Pump for SX-13CC/SX-13CCZA

GPD25-8S hot water circulating pump

We offer a small range of circulating pumps to suit a variety of applications.

An essential part of any hydronic heating system is the circulating pump or pumps.

The following table lists a range of circ. pumps to compliment our Air Sourced Hydronic Heat Pumps as primary circuit pump between the heat pump and the buffertank, and as the 'zone' pump(s) which circulate the water between the buffertank and the floorcoils and/or radiator panels.

The primary circulation pump must be matched to the flow-rate required by the heat pump.

The secondary or zone pumps are usually 0.5 to 1.5 Litres per second.

Some of our circulating pumps have 3 speeds to allow for varying conditions:

Model

Body

Speed

Conn's

Head

Watts

Flow Rate

R.R.P.

Comment

>GPD25-6<

C.I.

3 sp

25mm

2.5m

100/70/55

0.8L/s

$216

hydronics zone pump

>GPD25-8<

C.I.

3 sp

25mm

8m

245/190/145

1.4L/s@5m

$338

hydronics single-zone pump

>GPD32-9<

C.I.

1 sp

32mm

5m

300

1.6L/s@5m

$497

primary circuit pump (close-coupled buffertank)

>GPD25/32-12<

C.I.

1 sp

32mm

8m

500

1.4L/s

$610

primary circuit pump (remote buffertank)

 

Recommend Purpose-made stainless steel buffertank

With the SX-13CC/SX-13CCZA we recommend using a 100Lt or 200Lt buffertank.

Installing a buffertank on a hydronic heat-pump allows for zoning without causing backpressure or flow-rate fluctuations which may trip the heat-pump.

Hydronic Buffertanks also reduce short-cycling which increases efficiency.

With a heat-pump hydronic system, heat energy is always readily available so a larger "Heat-Energy-Storage" tank is not necessary and in fact can reduce efficiency. (one reason why we don't recommend multiple potable hot water heat-pumps for hydronics)

Skyline Energy 200SSBT Hydronic Buffertank-250

Other Models:

Simplified rules for sizing your heatpump for hydronic heating

- for MAXIMUM EFFICIENCY AND SERVICE LIFE!

  • Calculate how many kW are required
  • Look at the climatology of the location to establish the duration of 0oC to +4oC. Donít just look at the extreme temps, look at the mean overnight temp and duration
  • If the ambient air temp rarely dips below +4oC or does so for short periods then you can use this simple calculation...
    3 x electricity input kW = heatpump output heat kW to size the heatpump.
  • If the mean overnight ambient air temp is between 0oC and +4oC change the calculation to
    2 x electricity input kW = heatpump output heat kW to size the heatpump.
  • A more powerful heatpump will raise the water temp more rapidly so it will cycle off before it needs to defrost,
    thereby maintaining a higher COP and efficiency.
  • Warranty service may be refused if our sizing guidlines are ignored.

MODEL

POWER

COMPRESSOR

AIR DISCHARGE

5 STAR CAPABILITY

 

 

QTY

Brand Model

 

(5 star energy construction rating)

220V 1ph

>> SX-04

220V, 1ph

1x

Rotary 0.98kW

1x fan - side

for up to 35sqm radiators or 45sqm slab

>> SX-06

220V, 1ph

1x

Rotary 1.34kW

1x fan - side

for up to 48sqm radiators or 60sqm slab

>> SX-07

220V, 1ph

1x

Rotary 1.5kW

1x fan - side

for up to 55sqm radiators or 70sqm slab

>> SX-08

220V, 1ph

1x

Rotary 1.87kW

1x fan - side

for up to 67sqm radiators or 85sqm slab

>> SX-13CC/ZA

220V, 1ph

1x

Copeland ZW34

2x fan - side

for up to 100sqm radiators or 130sqm slab

>> SX-17CC/ZA

220V, 1ph

1x

Copeland ZW47

2x fan - side

for up to 140sqm radiators or 170sqm slab

 

 

 

 

 

 

220V 1ph or 2ph

>> SX-24/ZA

220V 1 or 2ph

2x

Copeland ZW34

2x fan - top

for up to 200sqm radiators or 240sqm slab

>> V25/ZA

220V 1 or 2ph

2x

Copeland ZW34

2x fan - V evap, top

for up to 210sqm radiators or 250sqm slab

>> V35/ZA

220V 1 or 2ph

2x

Copeland ZW47

2x fan - V evap, top

for up to 300sqm radiators or 350sqm slab

>> V42/ZA

220V 1 or 2ph

2x

Copeland ZW52

2x fan - V evap, top

for up to 340sqm radiators or 420sqm slab

 

 

 

 

 

 

380V 3ph

>> V42-3

380V 3ph

2x

Copeland ZW61

2x fan - V evap, top

for up to 350sqm radiators or 420sqm slab

>> V50-3

380V 3ph

2x

Copeland ZR72

2x fan - V evap, top

for up to 400sqm radiators or 500sqm slab

>> V60-3

380V 3ph

2x

Copeland ZW79

2x fan - V evap, top

for up to 480sqm radiators or 600sqm slab


Please call for trade pricing

For all enquiries, please call the national number below

or email